PENTAX Medical INSPIRA and EndoManager® EMS

The PENTAX Medical INSPIRA (EPK-i8020c) sends stills and video straight to EndoManager EMS by DICOM, so no capture PC is needed in the room. Patients come from the DICOM worklist. EMS accepts video over DICOM in MPEG-4 format only. EM4 isn't needed. Some sites add an EndoManager EM4 capture station anyway so every room works the same way.

DICOM direct to EMS
PENTAX Medical INSPIRA GI video processor DICOM EndoManager EMS HL7 EHR One per workflow
EM4 capture client
PENTAX Medical INSPIRA GI video processor via EndoManager 4 EM4 EndoManager EMS HL7 EHR One per workflow
FeatureDICOM direct to EMSEM4 capture station (optional)
ConnectionNetwork: DICOM Modality Worklist + C-StoreVideo cable + camera trigger
Capture PC in the roomNoYes (EM4)
Still imagesYesYes
VideoYesYes
ControlNoneBasic camera trigger cable into EM4
Capture triggered from the scopeNoYes, through EM4
Patient details sent to the processorNoNo
Scope serial number detectionNoNo

The DICOM path needs Pentax's OS-123 DICOM option on the processor.

On the DICOM path, no EM4 and no trigger are used. If you choose EM4 for the INSPIRA room, a basic camera trigger cable fires captures into EM4. Some sites do this for consistency: for example, a site with three Olympus EVIS X1 rooms, which need EM4, may put EM4 in its INSPIRA room too, so staff get the same experience in every room.

What's not supported

  • Patient name or demographics sent to the processor
  • Scope serial number detection

Where images go

EMS forwards images to your EHR, a PACS or VNA, or Epic Gallery. For Epic organizations, images go to the Lumens procedure note. Epic integration

Frequently asked questions

Does the INSPIRA need a capture PC?

No. It sends stills and video to EndoManager EMS by DICOM. EM4 is optional.

What video format does EndoManager accept over DICOM?

MPEG-4 only.

Why add an EM4 capture station?

For consistency. Sites that already run EM4 in other rooms, such as Olympus EVIS X1 rooms, may add it to the INSPIRA room so staff use the same workflow everywhere. A basic camera trigger cable then fires captures into EM4. It doesn't add scope detection or send the patient's name to the processor.

Compatibility depends on equipment model, software version, and site configuration. Listings and workflow diagrams are for planning only. Your NewCura team confirms every workflow before quoting.