Scope and processor compatibility

If it produces a visible-light image and has a video output, EndoManager® can capture it. Newer processors that support DICOM can send images straight to EndoManager EMS. Everything else connects through an EM4 capture station. Supported processors get full RS232 control; other devices use a camera trigger or a foot pedal. Mixed fleets are normal: you can connect any number of devices, from any brand, to one EMS.

Three ways to connect

PathHowWhat you get
DICOM direct to EMSNetwork: DICOM Modality Worklist + C-StorePatient from the worklist, stills to EMS, no capture PC in the room
EM4 with bi-directional controlVideo cable + RS232 to the processorStills and MPEG-4 video, demographics to the processor, scope serial detection, triggers from the scope
EM4 with trigger or foot pedalVideo cable + camera trigger or foot pedalStills and MPEG-4 video from any visible-light device with a video output

By specialty

  • GI video processors: Fujifilm ELUXEO and EPX, Olympus EVIS X1 / EXERA, PENTAX Medical INSPIRA and OPTIVISTA, among others. Current models can use DICOM direct or EM4 (one path per room; for example the ELUXEO 8000 offers both options).
  • Pulmonary: bronchoscopy on GI processors, plus systems such as the Olympus DVM-B2, which sends stills by DICOM (recording video needs an EM4 capture station).
  • ENT and laryngoscopy: Karl Storz, Olympus VISERA, Inventis and others, through EM4.
  • Speech pathology (FEES and stroboscopy): ATMOS, PENTAX Medical and XION stroboscopy systems, through EM4.
  • Urology: flexible cystoscopes and single-use ureteroscopes, through EM4.
  • Single-use scopes: Ambu and Boston Scientific systems.
  • Surgical and OR cameras: Karl Storz, Olympus, Richard Wolf and Stryker camera platforms, through EM4.
  • Ultrasound / EUS: captured through the host processor.

Search every model in the integration library →

Frequently asked questions

Does EndoManager work with mixed scope brands?

Yes. Any number of devices, from any brand, can feed one EMS.

Do I need a capture PC in every room?

No. Rooms whose processor sends stills by DICOM don't need one. For most devices, video recording uses EM4; some devices, such as PENTAX INSPIRA and Ambu, can send MPEG-4 video directly by DICOM. Choose EM4 where the equipment can't send DICOM, or where you want RS232 control.

What if my device isn't listed?

If it produces a visible-light image and has a video output, EM4 can capture it with a foot pedal, or the camera's trigger where available. Ask us to confirm.

Compatibility depends on equipment model, software version, and site configuration. Listings and workflow diagrams are for planning only. Your NewCura team confirms every workflow before quoting.